Fibrograts Logo
FRP Storage Tanks · Power Generation Industry

FRP Tanks for Power Plants

Abrasion and corrosion-resistant FRP tanks for FGD lime/gypsum slurry, ash handling, DM water, and chemical dosing systems — built to outlast coated steel in erosive, chemical-heavy duty.

ISO Certified Manufacturing
Exporting to 10 Countries
Fire-Retardant Certified
500+ Corporate Clients
Custom Sizes Available
2009MANUFACTURING SINCE
500+CORPORATE CLIENTS
20INDIAN STATES SERVED
10COUNTRIES EXPORTED TO

FGD slurry and DM plant chemicals wear through coated steel fast

Lime/gypsum slurry, ash handling systems, and DM plant chemical dosing put both abrasion and corrosion stress on tanks simultaneously. Coated mild steel wears through at the coating first; FRP's resistance is built into the material itself.

Abrasion Resistant
Reinforced internal layer withstands erosive lime, gypsum, and ash slurry without wearing through.
Chemical Dosing Ready
Vinyl ester systems handle sulphuric acid, caustic, and hydrazine dosing duties in DM plants.
No Corrosion
Unaffected by the moisture and chemical exposure typical of FGD and ash-handling areas.
Low Lifecycle Cost
No recoating cycles — critical for tanks in hard-to-access plant areas.

Where FGPL FRP tanks can be useful in power plants

01FGD lime & gypsum slurry tanks
02Ash slurry sumps & holding tanks
03DM plant chemical dosing (acid, alkali, hydrazine)
04Cooling tower makeup water storage
05Boiler feed & softened water tanks
06Scrubber feed and recirculation tanks
07Plant ETP equalisation tanks
08Fire water & utility storage

Standard build specification

ParameterSpecification
Capacity range500 L – 100,000+ L (vertical, horizontal & rectangular)
Resin systemsIsophthalic polyester (utility duty), Vinyl ester (dosing & slurry duty)
Abrasion protectionReinforced internal layer for lime/gypsum/ash slurry service
Operating temperatureUp to 90°C standard, higher on request with novolac vinyl ester
Design standardsEN 13121-3: Standard for designing and manufacturing above-ground FRP/GRP tanks and vessels. ASTM D4097: Standard for contact-molded FRP tanks for storing aggressive chemicals above ground at atmospheric pressure.
FittingsANSI B16.5 is an internationally recognized standard for pipe flanges and flanged fittings, which is followed by us for nozzles, fittings
CertificationISO 9001:2015 manufacturing; test reports on request

← swipe to see more →

FRP vs Coated Mild Steel vs Rubber-Lined Steel for power plant tanks

FactorFRP TankCoated Mild SteelRubber-Lined Steel
Abrasion resistanceExcellent — reinforced layerCoating wears throughModerate
Corrosion resistanceExcellent — inherentFails once coating breachesGood, until lining fails
MaintenanceMinimalFrequent recoatingPeriodic re-lining
Service life15–25+ years5–8 years8–12 years

← swipe to see more →

Get a tank built for your plant's FGD, ash, or DM system

Share your slurry composition, chemical dosing requirement, and capacity — FGPL's engineering team will recommend the right design within 24 business hours.

Request a Quote

Frequently asked questions

Yes. FGPL builds FGD (Flue Gas Desulfurization) slurry tanks with an abrasion-resistant laminate designed to handle the erosive lime and gypsum slurry used in FGD systems without wearing through, unlike coated mild steel.
Enquiry

Request a Quote for FRP Products

Selected country India, calling code +91

Your details are only used to respond to your enquiry.

  1. Send your requirement

    Product, size, quantity and where it's headed — a drawing helps, but isn't needed to start.

  2. We review and quote

    Our engineers check feasibility, resin grade and lead time, then come back with a costed proposal.

  3. Manufacture and dispatch

    Approved drawings go to our Indore plant, and we ship across 20 states and 10 countries.

CallGet a Free Quote